| SPECIFICATION | |||||||||||
| OUTPUT | MODEL NO. | MCNT1462000 | MCNT1463000 | MCNT2921000 | MCNT2922000 | MCNT4381000 | MCNT5471000 | MCNT5841000 | MCNT7300500 | ||
| OUTPUT VOLTAGE | 8-14.6V | 8-14.6V | 16-29.2V | 16-29.2V | 24-43.8V | 30-54.75V | 32-58.4V | 40-73V | |||
| OUTPUT CURRENT | 2A | 3A | 1A | 2A | 1A | 1A | 1A | 0.5A | |||
| OUTPUT POWER | 29.2W | 43.8W | 29.2W | 58.4W | 43.8W | 54.7W | 58.4W | 36.5W | |||
| PFC (MIN.) | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | |||
| RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 300mVp-p | 300mVp-p | 400mVp-p | 600mVp-p | 650mVp-p | 730mVp-p | |||
| INPUT | INPUT VOLTAGE | 100 ~ 240VAC | |||||||||
| FREQUENCY | 50 / 60Hz | ||||||||||
| INPUT POWER | NO LOAD: 0.5W MAX AT INPUT 100-240VAC 50/60Hz . LOADING : 100W MAX , AT RATED OUTPUT . | ||||||||||
| TEMPERATURE RISING | CASE 65 ℃ MAX FOR RATED OUTPUT | ||||||||||
| EFFICIENCY (MIN) | 88% | ||||||||||
| DIELECTRIC WITHSTAND TEST | 5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND | ||||||||||
| PROTECTION | OVER LOAD | THE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT | |||||||||
| SHORT CIRCUIT: | CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY | ||||||||||
| ENVIRONMENT | WORKING TEMP | THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 ℃ TO +45 ℃ | |||||||||
| STORAGETEMPERATURE | THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 ℃ TO +75 ℃ | ||||||||||
| RESISTANCE TO HEAT | WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3℃ FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM | ||||||||||
| RESISTANCE TO MOISTURE | THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 ± 2 ℃ AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER. | ||||||||||
| SAFETY & EMC | SAFETY STANDARDS | UL62368 EN60335 | |||||||||
| EMI | CISPR22 CLASS | ||||||||||
| INSULATION | B | ||||||||||
| OTHERS | MTBF | THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25 ℃ | |||||||||
| CONNECTOR | PLUG | 5521, 5525, RCA, XLR, XT60, M16, C14. | |||||||||
| CABLE | UL2464 18# 1M length | ||||||||||